Miniature Endoscope Camera Module

Miniature Endoscope Camera Module

Details
0.16MP 30fps | OV6946 | Ultra-Miniature Medical Endoscope | 1/18" Optical Format
Category
0.3MP Camera Module
 
Add To Inquiry
Send Inquiry
Chat Now
Description
Technical Parameters

Miniature Endoscope Camera Module | HX6946 for Medical & Industrial Endoscopy

▐ Products Description

Compact Imaging for Space-Constrained Endoscopic Equipment

The HX6946 miniature endoscope camera module uses the OV6946 CMOS image sensor, with a resolution of 400 × 400 pixels and a 1/18-inch optical format. Its small sensor format makes it suitable for endoscopic equipment where the available space for the imaging assembly is extremely limited. Unlike conventional camera modules used in general-purpose imaging devices, an endoscope module must fit within a narrow optical and mechanical design while maintaining a usable image for inspection or observation.

 

In practical endoscope development, the sensor is only one part of the imaging system. Lens diameter, optical alignment, working distance, illumination, and the internal diameter of the instrument all influence the final image. A compact sensor helps with size constraints, but the lens and lighting arrangement still need to be evaluated against the actual inspection environment.

 

The HX6946 uses a 1.75 μm × 1.75 μm pixel size, rolling shutter, and RGB Bayer output at up to 30 fps. It can be considered for miniature medical and industrial endoscopy projects. During OEM development, mechanical dimensions, optical requirements, electrical connections, and the target image-processing platform should be reviewed together before finalizing the module configuration.

 

Download Datasheet PDF

▐ Core Features

400 × 400 Resolution | 0.16 MP

1/18-Inch OV6946 CMOS Sensor

1.75 μm Pixel Size | 30 fps

Compact Endoscopic Imaging Configuration

▐ Technical Specification

Item Specification
Model HX6946
Image Sensor OV6946 CMOS
Maximum Resolution 400 × 400
Mega Pixels 0.16 MP
Pixel Size 1.75 μm × 1.75 μm
Optical Format 1/18 inch
Shutter Type Rolling Shutter
Frame Rate 30 fps
Chroma RGB Bayer
Dynamic Range 65.8 dB
Signal-to-Noise Ratio 36.8 dB
Sensitivity 1000 mV/lux-sec
Supply Voltage 3.3 V
Package Type CSP
Active Array 400 × 400
Imaging Area 714 × 707 μm
Dark Current 42 e⁻/sec
Ray Angle 25°
Applications Medical Endoscopy / Industrial Endoscopy

▐ Sensor Introduction

The OV6946 is a miniature CMOS image sensor with a 1/18-inch optical format and a 400 × 400 active pixel array. Its 1.75 μm pixel pitch and CSP package are relevant to endoscopic designs where the imaging electronics must occupy very little space. The sensor operates with a 3.3 V supply and uses a rolling shutter, with a specified frame rate of 30 fps.

For endoscopic imaging, sensor resolution should be considered alongside the optical system. The lens diameter, field of view, focus distance, illumination level, and the distance between the sensor and the optical assembly all affect the image presented to the operator. A small sensor alone does not determine the final image quality.

The OV6946 also has a specified dynamic range of 65.8 dB, signal-to-noise ratio of 36.8 dB, and sensitivity of 1000 mV/lux-sec. These values provide useful reference points during component selection, although actual imaging performance depends on the lens, illumination, exposure settings, and downstream image processing.

▐ Product Advantages

01

Small Sensor Format for Restricted Installation Spaces

The 1/18-inch OV6946 sensor is suited to miniature imaging assemblies. This is particularly relevant when an endoscope has a narrow insertion section and limited room for the camera electronics. The final module dimensions still depend on the PCB, lens assembly, and connection method.

02

Defined Image Output for Embedded Processing

RGB Bayer output at 400 × 400 resolution and 30 fps gives the system designer a defined starting point for image processing. Demosaicing, color correction, display scaling, and other processing functions depend on the receiving platform and its software implementation.

03

Optical Parameters Can Be Evaluated as a Complete Assembly

In an endoscope, lens selection has a direct effect on field of view, working distance, distortion, and image brightness. Matching the optics to the OV6946 sensor is therefore an important part of the development process, especially when the available front-end diameter is restricted.

04

A Practical Starting Point for OEM Endoscope Development

The HX6946 can be evaluated for medical or industrial endoscope projects. PCB dimensions, FPC routing, connector placement, optical alignment, and the target processing interface should be reviewed against the mechanical drawings before prototype approval and production planning.

▐ Why Choose Our Endoscope Camera Modules

 
 

Engineering Evaluation Before Finalizing the Module

Endoscope projects often have strict limits on camera diameter, optical length, and cable routing. These mechanical conditions need to be considered alongside sensor selection. Reviewing the application and available installation space early helps identify potential issues before the first prototype is assembled.

 

 
 
 

Adaptation to the Customer's Mechanical Design

PCB outline, component placement, FPC direction, connector position, and lens mounting can all affect the way a camera module fits inside an endoscope. These details can be reviewed during OEM development according to the customer's drawings and interface requirements.

 
 
 

Prototype Evaluation and Production Coordination

Optical alignment, image output, electrical compatibility, and mechanical fit should be checked during sample evaluation. Once the configuration is confirmed, the same key specifications can be carried forward into production inspection and batch consistency checks.

 

▐ Application

industrial Endoscope
Medical Endoscopy Equipment
Medical Imaging
Minimally Invasive Imaging Instruments
product-496-317
Industrial Borescope Inspection
industrial endoscope
Precision Internal Inspection Equipment

▐ Certifications & Quality Assurance

 
ISO9001_20260715

ISO 9001

ISO45001_20260715

ISO 45001

ISO14001_20260715

ISO 14001

TX EMC Test certificate20260715

EMC Test

CE CERTIFICATE 2 20260715

CE Certified

▐ Customization Service

An endoscope camera module has to fit both the optical design and the mechanical structure of the instrument. A change in lens diameter, working distance, or FPC routing may affect the available internal space and the assembly process. For OEM projects based on the HX6946, customization requirements can be reviewed around the sensor, optical configuration, PCB layout, and electrical connection.

Lens366x438
 

Lens & Optics

view more

Sensor366x438
 

Sensor

view more

Shape
 

Mechanical Design

view more

Connector2
 

Connector & I/O

view more

▐ FAQ

 

Q1: What is the HX6946 miniature endoscope camera module?

+

-

The HX6946 is a compact camera module based on the OV6946 CMOS image sensor. It features a 400 × 400 resolution, 1/18-inch optical format, and 30 fps frame rate. It is intended for evaluation in miniature medical and industrial endoscopic imaging equipment.

Q2: Is 400 × 400 resolution sufficient for an endoscope?

+

-

That depends on the inspection task, viewing distance, and required level of detail. For a miniature endoscope, resolution must be considered together with lens performance, illumination, and the display or processing system. The 400 × 400 output should be evaluated using representative samples from the actual application.

Q3: What should be considered when selecting a lens for the OV6946?

+

-

Lens diameter, field of view, working distance, focus range, distortion, and optical alignment should all be considered. The available installation space at the front end of the endoscope is also important. The final lens configuration needs to be checked against the intended inspection distance and image requirements.

Q4: Can the HX6946 be customized for an OEM endoscope project?

+

-

Customization requirements can be evaluated according to the project drawings and system specifications. Relevant items may include PCB dimensions, lens configuration, FPC routing, connector position, and mechanical mounting. The feasibility of each change depends on the selected hardware and available installation space.

Q5: What information is needed for an endoscope camera module quotation?

+

-

Useful information includes the intended application, target resolution, required frame rate, lens diameter, field of view, working distance, available PCB space, cable or connector requirements, electrical interface, and estimated order quantity. Mechanical drawings or reference images of the existing endoscope structure are also helpful when evaluating a customized configuration.

 

Hot Tags: miniature endoscope camera module, China miniature endoscope camera module manufacturers, commercial camera board, dental camera webcam, industrial camera imaging module, inspection camera camera module, inspection camera usb webcam, with ir usb camera

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!